- Joint Pipe Bore Size: 2"
- Coupling Type: join
- Measurement Range: 60 to 6045 Nm3 per hour
- Model Number: STTTMFMDN150
- DIY Supplies: ELECTRICAL
- Brand Name: Svit SensoPlan by Trumsense
- Origin: Mainland China
- Certification: NONE
- Power Supply: DC 24V
- Accuracy: 1.5%
- Output: 4 to 20mA and RS485
- Pressure: 16 bar
- Medium: Natural gas
- Material: SS 304
- Protection: IP65
- Size: DN150 6 inch
- other sizeand specification: available for customized production
Trumsense STTTMFMDN150 Thermal Gas Mass Flow Meter
Model: STTTMFMDN150
Material: SS304
Size: DN150
Flow Range: 60~6045 Nm3/H
Power Supply: DC 24
Output: 4 to 20mA + RS485 modbus
Accuracy: ±1.5%
Pressure: 16 bar
Installation Type: Insert type
Suitable Medium: Natural gas
Interface Language: English
Display: LCD screen
1. Elite Features of Trumsens Brand Thermal Gas Mass Flow Meter:
● Measuring the mass flow or volume flow of gas Do not need to do temperature and pressure compensation in principle with accurate measurement and easy operation.
● Wide range: 0.5Nm/s~1000Nm/s for gas. The meter also can be used for gas leak detection
● Good vibration resistance and long service life. No moving parts and pressure sensor in transducer, no vibration influence on the measurement accuracy.
● Easy installation and maintenance. If the conditions on site are permissible, the meter can achieve a hot-tapped installation and maintenance. (Special order of custom-made)
● Digital design, high accuracy and stability
● Configuring with RS485 or HART interface to realize factory automation and integration
2: Introduction of Trumsense brand thermal gas mass flow meter:
Thermal gas mass flow meter is designed on the basis of thermal dispersion, and adopts method of constant differential
temperature to measuring gas flow. It has advantages of small size,easy installation, high reliability and high accuracy, etc.
The meter contains two platinum resistance temperature sensors. The thermal principle operates by monitoring the cooling effect of a gas stream as it passes over a heated sensor. Gas flowing through the sensing section passes over two sensors one of which is used conventionally as a temperature sensor, whilst the other is used as a heater. The temperature sensor monitors the actual process values whilst the heater is maintained at a constant differential temperature above this by varying the power consumed by the sensor. The greater the gas velocity, the greater the cooling effect and power required to maintain the differential temperature. The measured heater power is therefore a measure of the gas mass flow rate.
3: Basic parameter of Trumsense Brand Thermal Gas Mass Flow Meter:
Due to space limitations, here can not show all the details of the parameters, please contact us to obtain the latest user manual.
4: Wiring of Trumsense Brand Thermal Gas Mass Flow Meter:
More detail, please contact us for the full version manual
5: Wholesales price
As you know, the satisfied quality must be based on reasonable price, but as the direct factory, we will offer you best price, based on your quantity. What we are chasing is long time cooperation, but not once or twice business.
6: Customzied Production is available
As the factory directly, we has strong ability to design, develop and produce based on user's special working application.Please feel freely conact us once the above parameter can not satisfy your needs. Below other designs,including various gas type are available in stock or production:
Due to space limitations, here can not show all the details of the parameters, please contact us to obtain the latest user manual.
7: Installation example from other buyers for Trumsese brand thermal gas mass flow meter:
Thermal meters require a fully developed flow profle as a prerequisite for correct flow
measurement. For this reason, please note the following points when installing the device.
●Obsenve the recommended inlet and outlet requirements.
●Good engineering practice is necessary for the associated pipe work and installation.
●Ensure correct alignment and orientation of the sensor.
●Take measures to reduce or avoid condensation (e.g. install a condensation trap,thermal insulation, etc.).
●The maximum permitted ambient temperatures and the medium temperature range,must be observed.
●Install the transmitter in a shaded location or use a protective sun shield.
●For mechanical reasons, and in order to protect the pipe, it is advisable to support heavy sensors. No installation in where large vibration exists
●No exposure in the environment containing a lot of corrosive gas
●No sharing power supply with frequency converter, electric welding machine and other machines which can make power-line interference. If necessary, please add power conditioner for transmitter power supply.
Due to space limitations, here can not show all the details of the installation instructions, please contact us to obtain the latest user manual.
8: You will recevie 2 sets quantity , the DN50 Thermal mass gas flow meter ,with model: STTTMFMDN150, same as below detail photos:
9: Troubleshooting of DN15 Trumsens Brand Hydrogen Mass Flow Meter :
10: Troubleshooting of DN15 Trumsens Brand Hydrogen Mass Flow Meter :
The Density and Conversion Coefficient of Common Gas
●According to different gas on site, the calibration in lab translates the flow rate of actual gas on site into flow rate of air, and then begins to calibrate the flow rate at present.
●Therefore, when using the meter on site, the meter displays mass flow or volume flow of actual gas.
●When translating the flow rate of gas into flow rate of air, there is a conversion coefficient table of different gas.
Table 1 The Density and Conversion Coefficient of Common Gas
11: Upper Range Value of Common Gas:
(Unit: Nm'/h. The follow table can be extended)
We are the original factory, if the above parameters can not satisfy your
specific needs, contact at any time, our technician team will offer you
the proposal within 24 hours.
Trumsense,china smart sensor,thermal gas mass flow meter,gas thermal mass flow meter,flowmeter,flow meter,vortex flowmeter,electromagnetic flowmeter,vortex flow meter,electromagnetic flow meter,thermal mass flow meter working principle,thermal mass flow meter,types of mass flow meter,mass flow meter,thermal water flow sensor,electromagnetic flowmeter,electromagnetic flow meter,how electromagnetic flow meter works,electromagnetic meter for water,electromagnetic flow meter for water,electromagnetic flow meter for gas,electromagnetic flowmeter for gas,best electromagnetic flow meter,trumsense,china smart sensor flowmeter,china smart sensor flow meter,trumsense flow meter,trumsense flowmeter,electromagnetic flowmeter, Eemerson flowmeter,electromagnetic vortex flowmeter,electromagnetic vortex flow meter,flowmeter vortex,flow meter vortex,rosemount flowmeter,rosemount flow meter,vortex flowmeter installation,vortex flow meter installation,vortex flowmeter manual, vortex flow meter manual, vortex flowmeter yokogawa,vortex flow meter yokogawa,what is vortex flowmeter,what is vortex flow meter,how do vortex flowmeters work,how do vortex flow meter work,vortex street flow meter,Hydrogen Mass Flow Meter,Hydrogen Mass FlowMeter, Trumsense,china smart sensor,thermal gas mass flow meter,gas thermal mass flow meter,flowmeter,flow meter,vortex flowmeter,electromagnetic flowmeter,vortex flow meter,electromagnetic flow meter,thermal mass flow meter working principle,thermal mass flow meter,types of mass flow meter,mass flow meter,thermal water flow sensor,how electromagnetic flow meter works,electromagnetic meter for water,trumsense,china smart sensor flowmeter,china smart sensor flow meter
Reviews
There are no reviews yet.